Medical category

Two level classification:

Model:KLM-A
    Product Introduction:

    Product NameMulti-parameter detector

    Product modelKLM-A

    Specification  ①.Suttlet weight150Kg

    ②.DimensionHost):Bout 100cm length×72cm width×250cm heigh

    ③.Host Input VoltageAC100V-240V 50Hz/60Hz 1.0A

    Product Main Structural Composition

    It consists of height module, weight module, blood pressure module, forehead temperature module, blood oxygen probe, electrode (handle electrode and foot electrode) integrated circuit, base support, power line and mobile main body.

    Intended purpose

    The multi-parameter detector is used to measure the blood pressure (systolic pressure, diastolic pressure, and pulse rate), forehead temperature, and blood oxygen (pulse oxygen saturation) for adult (Weight more than 30Kg, height more than 140cm) in the clinic.

    This product is certified as a medical device in the European Union under the Medical Device Regulation (EU) 2017/745 by SGS CE1639, exclusively for the indication(s) of “measurement of blood pressure, forehead temperature, blood oxygen”. Other medical/non-medical uses ascribed to this device are not within the scope of CE certification, and users should be aware product performance and/or safety has not been evaluated by SGS for those purposes。

    Product technical parameters

    Product Name

    Multi-parameter detector

    Model

    KLM-A

    Display Mode

    12.1inch touch LCD

    Blood pressure Measuring function

    Measurement methods

    oscillography measure

    Measuring range

    Pressure: 0kPa40kPa(0mmHg

    300mmHg)

    Pulse rate: 40 times/min199 times/min

    Accuracy rating

    pressure±0.4kPa(±3mmHg)

    Pulse rate±5%

    Arm circumferences

    about 22cm36cm

    Cuff pressure

    0300mmHg

    Clinical performance

    Blood pressure Measuring function was clinically investigated according to the requirements of EN ISO 81060-2:2019.

    Forehead temperature Measuring function

    Rated output range

    22.042.971.6109.2 

    Laboratory accuracy

    2242.9 ±0.3 

    Display Resolution

    0.1 (0.1)

    Measuring Site

    Forehead

    Reference Body Site

    Armpit

    Body mode

    Adjusted mode

    Clinical accuracy

    Clinical biasΔcb=-0.02 

    LIMITS OF AGREEMENT, LA=0.18 

    CLINICAL REPEATABILITY, σr,=0.07 

    Blood oxygen measuring function

    Measuring range

    70%100%

    Blood oxygen saturation measuring accuracy

    ±2%

    Height measuring function

    Measuring range

    80cm205cm

    Measuring accuracy

    ±1cm

    Weight measuring function

    Weighing range

    5kg300kg

    Maximum permissible

    error of weighing

    5 kg≤m≤50kg        ±0.3 kg

    50 kgm≤100 kg     ±0.4 kg

    100 kgm≤200 kg    ±0.8 kg

    200 kgm≤300 kg    ±1.0 kg

    Body impedance

    Impedance measurement range

    200Ω800Ω

    Accuracy

    ±10%

    Function

    a)

    Total moisture

    b)

    Protein

    c)

    Bone weight

    d)

    Fat weight

    e)

    Standard body weight

    f)

    Body mass index

    g)

    Percentage of body fat;

    h)

    waist-to-hip ratio

    i)

    skeletal muscle

    j)

    Visceral fat index

    k)

    Blood pressure

    l)

    Height value

    m)

    Physical age

    n)

    blood oxygen level

    o)

    body temperature

    p)

    basal metabolism

    q)

    voice broadcast

    Power Supply

    100V-240V 50Hz/60Hz 1A

    Rated power

    230VA

    Normal working conditions

    Ambient temperature540 

    Relative humidity15 % 90% RH

    Atmospheric pressure 700hPa

    1060hPa

    Transport and storage conditions

    Ambient temperature- 20 50 

    Relative humidity15% - 90% RH

    Atmospheric pressure 500hPa

    1060hPa

    DimensionHost 

    Bout 100cm length×72cm width×250cm heigh

    Protection against electric shock

    classequipment, BF type applied part

    Liquid intake protection classification

    IPX2

    Disinfection and sterilization method

    Clean as recommended by the manufacturer

    Safety classification

    Equipment not to be used in the presence of flammable anesthetic gas mixed with air or with oxygen or nitrous oxide

    Fuse

    T2AH250V 

    Running Mode

    continuous duty

    EMC

    1 group of class B devices




    Hotline
    +8613928121219
    © 2018 Zhongshan Jinli Electronic Welghing Equipment Co.,Ltd